Project 1 of 4 · New fluorophores

Found by accident. Kept on purpose.

A trace side product in a mass spectrum became a new, permanently locked dye family: bright, green and made for two-photon microscopes.

Fluorescent solutions in laboratory cuvettes

Why it matters

A new scaffold is rare.

Most fluorescent dyes in use belong to a handful of families, and combining high brightness with a large Stokes shift is hard. New core structures that compete with the best are rare.

This family is the main conceptual advance of my PhD: a fundamentally new fluorophore scaffold that performs on a par with the best small-molecule dyes.

The approach

Let the molecule close its own ring.

Our lab had locked GFP chromophore analogues with intramolecular hydrogen bonds. In those reactions, the mass spectra kept showing traces of a strongly fluorescent condensation product. We redesigned the chemistry so that this product became the main one: an OH group on the chromophore drives an intramolecular ring closure and forms a new fused heterocycle, the chromeno[2,3-d]imidazole.

  1. 1

    Notice

    A fluorescent by-product shows up in the mass spectrum.

  2. 2

    Force

    An OH group on the chromophore turns the ring closure into the main reaction.

  3. 3

    Optimize

    Tune the imidazolone part, extend the π-system and add sulfonyl groups for water solubility.

Spec sheet

First dye (DMSO)λabs 450 nm · λem 520 nm · ε 60 000 M⁻¹ cm⁻¹ · Φ 0.9
Tuned for microscope lasersλabs 480 nm · λem 538 nm · ε×Φ 37 000 M⁻¹ cm⁻¹
Water-soluble generationλex 502 nm · λem 560 nm · ε×Φ 27 000 M⁻¹ cm⁻¹ in water
Stokes shift58–70 nm
Two-photonaction cross sections among the best fluorophores; the same transition as one-photon, so the two-photon wavelength is predictable
pHprotonation shifts the color to the red (pKa ≈ 5)
Functional probes4 — cell membrane, mitochondria, HaloTag ligand, antibody label

In the microscope

Cell membranes of HEK-293 cells after 10 minutes with 100 nM of the membrane probe. Two-photon excitation at 920 nm, detection 480–550 nm, 1.25 mW.
Cell membranes of HEK-293 cells after 10 minutes with 100 nM of the membrane probe. Two-photon excitation at 920 nm, detection 480–550 nm, 1.25 mW.
Close-up of stained membranes, same conditions.
Close-up of stained membranes, same conditions.
Co-stained with the commercial membrane dye MemBright Cy5.5 (red).
Co-stained with the commercial membrane dye MemBright Cy5.5 (red).
Mitochondria in HEK-293 cells (10 µM probe, 10 min), two-photon time-lapse at 920 nm.
HER2-positive 3T3 cells stained with the dye attached to the antibody trastuzumab. With Mikako Ogawa, Hokkaido University.
HER2-positive 3T3 cells stained with the dye attached to the antibody trastuzumab. With Mikako Ogawa, Hokkaido University.

Papers

Patent application HUP250338

Patent

Manuscript in preparation

In preparation